Detail LUTRON LCR-9184
Features:
19999/ 1999 counts dual LCD display
Auto LCR smart check and measurement.
Test range : ( ex : F = 1 KHz)
L : 200.00 uH to 2000.0 H
C : 2000.0 pF to 2.000 mF
R : 20.000 to 200.0 M
Series/ Parallel modes are selectable.
DCR mode 200.00 to 200.0M
Five test frequency are available :
100 Hz/ 120 Hz/ 1 KHz/ 10 KHz/ 100 KHz
Ls/ Lp/ Cs/ Cp with D / Q / / ESR Parameter.
LCD Display with backlight structure.
Power : DC 9V battery or DC 9V adapter in.
RS232/ USB computer interface.
Optional SMD test clips, SMDC-21.
Optional SMD tester, SMDA-22.
Optional USB cable, USB-01.
Optional data acquisition software, SW-E803.
Optional holster, HS-03.
GENERAL SPECIFICATIONS
Display: LCD size: 56.4 x 52.9 mm
LCD with green backlight ( ON / OFF)
Test frequency: 100 Hz/ 120 Hz/ 1 KHz/ 10 KHz/ 100 KHz
Function: L/ C/ R Function selector
Frequency selector
D/ Q/ 0/ ESR selector
Sorting mode selector
Backlight
Dissipation and Quality Factor: 0.000 to 999
0 Measurement: ± 90°
Sorting tolerance mode: ± 0.25% , ± 0.5% , ± 1% , ± 2% , ± 5%
± 10% , ± 20% , + 80% -20%
Calibration: Open/ Short calibration
Data Hold Freeze the display reading
Data output: RS 232/ USB PC computer interface.
Power off: Auto shut off saves battery life or manual off by push button
Operating temperature: 0° C to 50° C
Operating humidity: < than 85% RH
Power supply: 006P DC 9V battery or equivalent. Alkaline or Heavy duty type
DC 9V adapter input ( AC/ DC power adapter is optional)
Power consumption: DC 35mA approx.
Dimensions: 193 x 88 x 41 mm
Weight: 420 gr. meter only
ELECTRICAL SPECIFICATIONS ( 23° C ± 5° C)
RESISTANCE ( DCR)
Range
Accuracy
Remark
20 Ohm ± ( 0.5% + 5d) After Short CAL.
200 Ohm
2 kOhm
20 kOhm
200 kOhm
2 MOhm After Open CAL.
20 MOhm ± ( 1% + 5d) After Open CAL.
200 MOhm ± ( 2% + 5d) After Open CAL.
RESISTANCE ( Rp/ Rs)
Range
Accuracy
Accuracy
Remark
100 Hz/ 120 Hz
1000 Hz
20 Ohm ± ( 1% + 5d) ± ( 1% + 5d) After Short CAL.
200 Ohm ± ( 0.5% + 5d) ± ( 0.5% + 5d)
2 kOhm
20 kOhm
200 kOhm
2 MOhm ± ( 1% + 5d) ± ( 1% + 5d) After Open CAL.
20 MOhm ± ( 1% + 5d) ± ( 2% + 5d) After Open CAL.
200 MOhm ± ( 2% + 5d) ± ( 5% + 5d) After Open CAL.
Range
Accuracy
Accuracy
Remark
10 kHz
100 kHz
20 Ohm ± ( 1% + 5d) ± ( 2% + 5d) After Short CAL.
200 Ohm ± ( 0.5% + 5d) ± ( 0.5% + 5d)
2 kOhm
20 kOhm
200 kOhm
2 MOhm ± ( 1% + 5d) ± ( 2% + 5d) After Open CAL.
20 MOhm ± ( 2% + 5d) ------------- After Open CAL.
CAPACITANCE ( Cp/ Cs) : D < 0.1
Range
Accuracy
Accuracy
Remark
100 Hz/ 120 Hz
1000 Hz
20 pF ± ( 2% + 5d) ± ( 1% + 5d) After Open CAL.
200 pF ± ( 1% + 5d) ± ( 1% + 5d) After Open CAL.
2000 pF ± ( 0.8% + 5d) ± ( 0.8% + 5d) After Open CAL.
20 nF ± ( 0.5% + 5d) ± ( 0.5% + 5d)
200 nF
2000 nF
20 uF
200 uF After Short CAL.
2000 uF ± ( 1% + 5d) ± ( 1% + 5d) After Short CAL.
20 mF ± ( 2% + 5d) --------------- After Short CAL.
Range
Accuracy
Accuracy
Remark
10 kHz
100 kHz
20 pF ± ( 1% + 5d) ± ( 1% + 5d) After Open CAL.
200 pF ± ( 0.5% + 5d) ± ( 0.5% + 5d) After Open CAL.
2000 pF After Open CAL.
20 nF
200 nF
2000 nF
20 uF ± ( 0.8% + 5d) ± ( 0.8% + 5d)
200 uF ± ( 1% + 5d) --------------- After Short CAL.
INDUCTANCE ( Lp/ Ls) : D < 0.1
Range
Accuracy
Accuracy
Remark
100 Hz/ 120 Hz
1000 Hz
20 uH ± ( 1% + 5d) ± ( 1% + 5d) After Short CAL.
200 uH After Short CAL.
2000 uH ± ( 0.8% + 5d) ± ( 0.8% + 5d)
20 mH ± ( 0.5% + 5d) ± ( 0.5% + 5d)
200 mH
2000 mH
20 H
200 H ± ( 0.8% + 5d)
2000 H ± ( 1% + 5d) ------------------- After Open CAL.
Range
Accuracy
Accuracy
Remark
10 kHz
100 kHz
20 uH ± ( 1% + 5d) ± ( 1% + 5d) After Short CAL.
200 uH ± ( 0.8% + 5d) ± ( 0.8% + 5d) After Short CAL.
2000 uH ± ( 0.5% + 5d) ± ( 0.5% + 5d)
20 mH
200 mH ---------------
2000 mH ---------------
Tampilkan Lebih Banyak