Detail FLUKE 120 MURAH MANTAP
Specifications:
Specifications
Oscilloscope Bandwidth
Fluke 125: 40 MHz
Fluke 124: 40 MHz
Fluke 123: 20 MHz
Dual input True RMS Meter
Vdc, Vac, Vac+ Vdc, Ohms, Continuity , Diode-test
Current, C, F, Capacitance, dBV, dBM, Crest Factor, Touch Hold and Zeroset
TrendPlot Recording
Automatic vertical scaling and time compression.
Display the actual, MIN, MAX and AVG reading.
Cursors
Fluke 125/ 124: T, 1/ T, V, V, rise- and fall time
Real-time sample rate
25 MS/ s
Equivalent sampling rate
up to 2.5 GS/ s ( 125, 124) or 1.25 GS/ s ( 123) .
Inputs and digitizers
2
Timebase range
Fluke 125/ 124: 20 ns - 1 min/ div
Fluke 123: 10 ns - 1 min/ div
Input sensitivity
5 mV - 500 V/ div
Trigger types
Connect-and-View? , Free Run, Single Shot, Edge, Video, External
Glitch capture
40 ns
Scope measurements
Automatic measurements: 26 ( all instruments) On top, Fluke 125 has additional measurement functions for Power ( W) , VA, VAR and Power Factor ( PF) for single phase and balanced-three-phase ( delta) power systems.
Harmonics mode
Fluke 125 has capbility to analyze the harmonics contents of power signals. See below for details.
Maximum record length
512 min/ max pts per input
Memory
Fluke 125/ 124: 20 screens and setups
Fluke 123: 10 screens and setups
Additional Power measurement capabilities ( Fluke 125 only)
Measurement types:
? Watt,
? VA,
? VAR,
? Power Factor ( PF)
Power configuration:
Single phase or balanced three-phase ( delta-configuration) mains supply
Voltage measurement
Channel A; using STL120, voltage probe or direct input
Current measurement
Channel B, using i400s ( included) or other compatible current clamp
Current Clamp or Shunt sensitivity:
0.1 / 1 / 10 / 100 / 1000 mV/ A, 10 mV/ mA and 400 mV/ A.
Harmonics Mode ( Fluke 125 only)
Converts waveform information into a harmonics display ( using FFT processing) which shows the relative amplitudes of the 1st up to the 33rd harmonic
Analyzed waveform:
Voltage waveform( Ch.A) , Current wavefrom ( Ch.B) or Power ( Ch.A x Ch.B) , automatically generated.
Harmonics Frequency range:
DC up to 33rd harmonic ( for fundamental up to 60 Hz) ;
DC up to 24th harmonic ( for fundamental up to 400 Hz) .
Display
Bargraph showing 1st up to 33rd harmonic and DC; amplitude displayed in % relative to fundamental
Measurements:
Relative amplitude of individual harmonics;
THD in % r or % f.
Environmental Specifications
Operating Temperature
0 C to 50 C
Storage Temperature
-20 C to + 60 C
Operating Altitude
3, 000 m
Safety Specifications
Electrical Safety
600V CAT III ( EN61010-1)
Mechanical & General Specifications
Size
232 x 115 x 50 mm
Weight
1.2 kg
Warranty
3-years on main instrument, 1-year on accessories
Battery Life
7 hrs using NiMH
RS232/ USB Interface
Optically isolated via optional PM9080 or OC4USB for interfacing
Tampilkan Lebih Banyak