Fluke 1625 GEO Earth Ground Testers

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
2 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 1625 GEO Earth Ground Testers

Fluke 1625 GEO Earth Ground Testers RA 3-pole ground resistance measurement ( IEC 1557-5) Measuring Voltage Fluke 1623 Vm = 48 V ac Fluke 1625 Vm = 20/ 48 V ac Short circuit current Fluke 1623 > 50 mA Fluke 1625 250 mA ac Measure frequency Fluke 1623 128 Hz Fluke 1625 94, 105, 111, 128Hz Resolution Fluke 1623 0.001 & to 10 & Fluke 1625 0.001 & to 100 & Measuring range Fluke 1623 0.001 & to 19.99 k& Fluke 1625 0.001 & to 299.9 k& Intrinsic error Fluke 1623 ± ( 2 % of reading + 3 digit) Fluke 1625 ± ( 2 % of reading + 2 d) Operating error Fluke 1623 ± ( 5 % of reading + 3 d) Fluke 1625 ± ( 5 % of reading + 5 d) RA 4-pole ground resistance measurement ( IEC 1557-5) Measuring Voltage Fluke 1623 Vm = 48 V ac Fluke 1625 Vm = 20/ 48 V ac Short circuit current Fluke 1623 > 50 mA Fluke 1625 250 mA ac Measure frequency Fluke 1623 128 Hz Fluke 1625 94, 105, 111, 128Hz Resolution Fluke 1623 0.001 & to 10 & Fluke 1625 0.001 & to 100 & Measuring range Fluke 1623 0.001 & to 19.99 k& Fluke 1625 0.001 & to 299.9 k& Intrinsic error Fluke 1623 ± ( 2 % of reading + 3 d) Fluke 1625 ± ( 2 % of reading + 2 d) Operating error Fluke 1623 ± ( 5 % of reading + 3 d) Fluke 1625 ± ( 5 % of reading + 5 d) RA 3-pole ground resistance measurement with current clamp Measuring Voltage Fluke 1623 Vm = 48 V ac Fluke 1625 Vm = 20/ 48 V ac Short circuit current Fluke 1623 > 50 mA Fluke 1625 250 mA ac Measure frequency Fluke 1623 128 Hz Fluke 1625 94, 105, 111, 128Hz Resolution Fluke 1623 0.001 & to 10 & Fluke 1625 0.001 & to 10 & Measuring range Fluke 1623 0.001 & to 19.99 k& Fluke 1625 0.001 & to 29.99 k& Intrinsic error Fluke 1623 ± ( 7 % of reading + 3 d) Fluke 1625 ± ( 7 % of reading + 2 d) Operating error Fluke 1623 ± ( 10 % of reading + 5 d) Fluke 1625 ± ( 10 % of reading + 5 d) RA 4-pole selective ground resistance measurement with current clamp Measuring Voltage Fluke 1623 Vm = 48 V ac Fluke 1625 Vm = 20/ 48 V ac Short circuit current Fluke 1623 > 50 mA Fluke 1625 250 mA ac Measure frequency Fluke 1623 128 Hz Fluke 1625 94, 105, 111, 128Hz Resolution Fluke 1623 0.001 & to 10 & Fluke 1625 0.001 & to 10 & Measuring range Fluke 1623 0.001 & to 19.99 k& Fluke 1625 0.001 & to 29.99 k& Intrinsic error Fluke 1623 ± ( 7 % of reading + 3 d) Fluke 1625 ± ( 7 % of reading + 2 d) Operating error Fluke 1623 ± ( 10 % of reading + 5 d) Fluke 1625 ± ( 10 % of reading + 5 d) Stakeless ground loop measurement Measuring Voltage Fluke 1623 Vm = 48 V ac Fluke 1625 Vm = 20/ 48 V ac Measure frequency Fluke 1623 128 Hz ( 125 Hz on request) Fluke 1625 94, 105, 111, 128Hz Noise current ( Iext) Fluke 1623 Max. Iext = 10 A ( ac) ( RA < 20 & ) Max. Iext = 2 A ( ac) ( RA 3000 measurements Fluke 1625 Typical 3000 measurements ( RE+ RH d 1 k& ) Typical 6000 measurements ( RE+ RH d 10 k& )
Tampilkan Lebih Banyak